- 판형 멤브레인 산기장치
- 디스크형 멤브레인
산기장치 - 튜브형 멤브레인 산기장치
- 피스톤 펌프
- Jet Control Valve
- Diaphragm
Control Valve - Flow Meter
Jet Control Valve

INSTALLATION PICTURE

DESIGN DETAIL
- Air flow range (min/average/max)
- Nominal size/nominal pressure of the counter flange
- Operating pressure (min/average/max)
- Operating temperature of the medium (min/average/max)
- Ambient temperature and conditions at site
- Supply drive voltage/ data transmission

DIMENSION

VACOMASS® jet control valve with an electric actuator VACOMASS® actuator, Type AUMA-SAR
Dimensions according to EN 1092-1/2 PN 10
Nominal pipe size DN | length L | A | B⑴ | DL | No. of holes |
---|---|---|---|---|---|
250 | 900 | 150 | F10 | 22 | 12 |
300 | 970 | 154 | F10 | 22 | 12 |
350 | 1,050 | 195 | F10 | 22 | 16 |
400 | 1,150 | 230 | F10 | 22 | 16 |
(1) according to EN ISO 5210
(2) depends on make and type of actuator
Nominal pipe size DN | Recommended air flow range in Nm³/h (depending on temperature and pressure) |
---|---|
250 | 80 - 4,000 |
300 | 100 - 5,000 |
350 | 130 - 6,500 |
400 | 160 - 8,000 |